en
  • en
  • cz
Catalog
Catalog

High-speed rolling gates of the SPEEDROLL SDI series

High-speed roller doors of the SPEEDROLL SDI series are designed for installation on internal openings of premises for any purpose (industrial, warehouse, retail, etc.) in order to isolate and preserve the microclimate.
Application:
  • Warehouse complexes. Industrial premises
Advantages
High opening speed — up to 2.5 m/s.
Reliable automation of our own production.
Possibility of installing various additional equipment: photocells, key buttons, drive and rack heating systems, etc.
Stable operation at significant negative temperatures.
High opening speed — up to 2.5 m/s.
Reliable automation of our own production.
Possibility of installing various additional equipment: photocells, key buttons, drive and rack heating systems, etc.
Stable operation at significant negative temperatures.
Design
Surface type
Frame colors
Canvas colors
Doors frame – zinc-coated steel, unpainted
Doors frame – zinc-coated steel, unpainted
Doors frame – ASIS 304 stainless steel
Doors frame – ASIS 304 stainless steel
RAL 9010 Pure white
RAL 9010 Pure white
RAL 5002 Ultramarine blue
RAL 5002 Ultramarine blue
RAL 6026 Opal green
RAL 6026 Opal green
RAL 9006 White aluminium
RAL 9006 White aluminium
RAL 1003 Signal yellow
RAL 1003 Signal yellow
RAL 3002 Carmine red
RAL 3002 Carmine red
RAL 2004 Pure orange
RAL 2004 Pure orange
RAL 9010 Pure white
RAL 9010 Pure white
RAL 5002 Ultramarine blue
RAL 5002 Ultramarine blue
RAL 6026 Opal green
RAL 6026 Opal green
RAL 9006 White aluminium
RAL 9006 White aluminium
RAL 1003 Signal yellow
RAL 1003 Signal yellow
RAL 3002  Carmine red
RAL 3002 Carmine red
RAL 2004  Pure orange
RAL 2004 Pure orange
Equipment
Standard
Optional
Tracks and track covers made of zinc-coated steel

Tracks and track covers made of zinc-coated steel

Zinc-coated shaft, diameter 90/130 mm

Zinc-coated shaft, diameter 90/130 mm

Guide rails — extruded polyethylene

Guide rails — extruded polyethylene

Door curtain — nontransparent reinforced PVC with density of 900–1 200 g/sqm

Door curtain — nontransparent reinforced PVC with density of 900–1 200 g/sqm

Control unit — painted steel body 300 х 400 х 150 mm; protection class — IP54; with frequency converter

Control unit — painted steel body 300 х 400 х 150 mm; protection class — IP54; with frequency converter

Photocells are installed at 500 mm above the floor level, and at the top of side tracks to detect incorrect unwinding of the curtain

Photocells are installed at 500 mm above the floor level, and at the top of side tracks to detect incorrect unwinding of the curtain

Tracks and track covers made of stainless steel AISI304, AISI316

Tracks and track covers made of stainless steel AISI304, AISI316

Control unit body made of stainless steel AISI304

Control unit body made of stainless steel AISI304

Heating of the drive and tracks

Heating of the drive and tracks

If the sensitive lower edge touches an obstruction when the door is closing, then a signal is transmitted to the control unit to open the door. In case of power outage the door opens automatically with a counterweight

If the sensitive lower edge touches an obstruction when the door is closing, then a signal is transmitted to the control unit to open the door. In case of power outage the door opens automatically with a counterweight

Technical description
Size Table
Construction
Standard Construction
Specifications
Operating Conditions
Parameters
Value
Opening width, mm
1,200–5,700
Opening height, mm
1,800–5,800
Headroom, mm
From 450
Sideroom clearance, mm
From 225
  1. Electric drive
  2. Shaft
  3. Shaft box
  4. Gate leaf
  5. Transparent insert (window/panel)
  6. Stand
  7. Guide for moving the web
  8. Bottom edge of the canvas
  9. Photocell
  10. Control unit
  11. Counterbalance

Drive on the side.

Drive on the side.

Symbol, parameter name Calculation formula
H, mm Opening height 1,600–5,700
B, mm Opening width 1,800–5,800
Front drive.

Front drive.

Symbol, parameter name Calculation formula
H, mm Opening height 1,600–5,700
B, mm Opening width 1,800–5,800
Parameter Value Notes
Wind load, Pa CLASS1 (up to 82) For gates 6,000 × 6,000 mm
Wind load, Pa CLASS2 (up to 90) For gates 5,000 × 5,000 mm
Opening speed, m/s 2.0 Gates up to 3,000 × 3,000 mm
Opening speed, m/s 1.5 Gates up to 5,000 × 5,000 mm
Opening speed, m/s 1,0 Gates up to 6,000 × 6,000 mm
Closing speed, m/s 0.5
Operating temperature range, °С -30…+50 When using the rack and drive heating system; when operating in a temperature range of -16…-30 °C, the gate design does not have reinforcement on the leaf, and transparent sections cannot be installed; "Security Profile" option is not available
Power, W 1,500
IP protection class 54 End positions are tracked by encoder
Supply voltage, V 220 V / 50 Hz Single phase
Supply voltage, V 380 V / 50 Hz Three-phase
Number of cycles 1,500,000 Depends on operating conditions
Wind load, Pa CLASS3 (up to 120) For gates 3,000 × 3,000 mm

Wind load resistance is given for SpeedRoll series doors in the closed position. Gates are not used in places with unstable and high wind loads caused by natural or man-made factors, such as: buildings located on sea coasts or in the mountains; multi-level heated underground parking lots with multiple entrances and exits; production facilities with powerful supply and exhaust ventilation; in buildings of complex configuration with many gate openings, where strong drafts may occur. If one or more of the above factors are present, it is recommended to use a SpeedFold series door or a HSSD series spiral door.

To ensure reliable and uninterrupted operation of the gate, it is recommended to carry out regular technical inspection and maintenance.

Manual opening and closing of the gate is done using a crank.

Do not subject the gate to impacts or interfere with its free opening and closing.

Do not allow the PVC sheet guide to get dirty.

It is prohibited to stand in the opening while the gate is opening and closing to avoid injury.

Make sure that there are no foreign objects in the opening when opening and closing the gate.

The self-healing function of the door leaf in the guides is used to operate the gate in emergency conditions, for example, in the event of an unintentional collision with a vehicle, and is not intended to work when the door leaf is deliberately and systematically knocked out of the guides. The functionality of the function is ensured by the ability of the “zipper” installed on the door leaf to come out of the plastic guides. The functionality of the function cannot be ensured in the event of impacts that exceed the strength parameters of the individual components of the web and system elements. For example, in the event of a collision with a road surface at high speed, impacts with sharp objects, impacts on the top of the gate with raised forks of a forklift, etc.

Additional Information print

All the DoorHan products are loaded with hydraulic crane or fork-lift truck with 2 m long forks. Customer or installer is recommended to use similar equipment. Truck fork should go under the wooden pallet, provided by the customer, and protrude from its other side. When lifting with crane or other lifting equipment use slings of corresponding lifting capacity.

Warranty print

The buyer is provided with a performance guarantee for high-speed rolling gates produced by the DoorHan concern for a period of 1 year for retail and for a period of 2 years for dealer orders from the date of purchase.

New Products
DoorHan SERVO drive (220 V).

DoorHan SERVO drive (220 V).

Design
Surface type
Doors frame – zinc-coated steel, unpainted
Doors frame – zinc-coated steel, unpainted
Doors frame – ASIS 304 stainless steel
Doors frame – ASIS 304 stainless steel
Frame colors
RAL 9010 Pure white
RAL 9010 Pure white
RAL 5002 Ultramarine blue
RAL 5002 Ultramarine blue
RAL 6026 Opal green
RAL 6026 Opal green
RAL 9006 White aluminium
RAL 9006 White aluminium
RAL 1003 Signal yellow
RAL 1003 Signal yellow
RAL 3002 Carmine red
RAL 3002 Carmine red
RAL 2004 Pure orange
RAL 2004 Pure orange
Canvas colors
RAL 9010 Pure white
RAL 9010 Pure white
RAL 5002 Ultramarine blue
RAL 5002 Ultramarine blue
RAL 6026 Opal green
RAL 6026 Opal green
RAL 9006 White aluminium
RAL 9006 White aluminium
RAL 1003 Signal yellow
RAL 1003 Signal yellow
RAL 3002  Carmine red
RAL 3002 Carmine red
RAL 2004  Pure orange
RAL 2004 Pure orange
Equipment
Standard
Tracks and track covers made of zinc-coated steel

Tracks and track covers made of zinc-coated steel

Zinc-coated shaft, diameter 90/130 mm

Zinc-coated shaft, diameter 90/130 mm

Guide rails — extruded polyethylene

Guide rails — extruded polyethylene

Door curtain — nontransparent reinforced PVC with density of 900–1 200 g/sqm

Door curtain — nontransparent reinforced PVC with density of 900–1 200 g/sqm

Control unit — painted steel body 300 х 400 х 150 mm; protection class — IP54; with frequency converter

Control unit — painted steel body 300 х 400 х 150 mm; protection class — IP54; with frequency converter

Photocells are installed at 500 mm above the floor level, and at the top of side tracks to detect incorrect unwinding of the curtain

Photocells are installed at 500 mm above the floor level, and at the top of side tracks to detect incorrect unwinding of the curtain

Optional
Tracks and track covers made of stainless steel AISI304, AISI316

Tracks and track covers made of stainless steel AISI304, AISI316

Control unit body made of stainless steel AISI304

Control unit body made of stainless steel AISI304

Heating of the drive and tracks

Heating of the drive and tracks

If the sensitive lower edge touches an obstruction when the door is closing, then a signal is transmitted to the control unit to open the door. In case of power outage the door opens automatically with a counterweight

If the sensitive lower edge touches an obstruction when the door is closing, then a signal is transmitted to the control unit to open the door. In case of power outage the door opens automatically with a counterweight

Technical description
Size Table
Parameters
Value
Opening width, mm
1,200–5,700
Opening height, mm
1,800–5,800
Headroom, mm
From 450
Sideroom clearance, mm
From 225
Construction
  1. Electric drive
  2. Shaft
  3. Shaft box
  4. Gate leaf
  5. Transparent insert (window/panel)
  6. Stand
  7. Guide for moving the web
  8. Bottom edge of the canvas
  9. Photocell
  10. Control unit
  11. Counterbalance
Standard Construction

Drive on the side.

Drive on the side.

Symbol, parameter name Calculation formula
H, mm Opening height 1,600–5,700
B, mm Opening width 1,800–5,800
Front drive.

Front drive.

Symbol, parameter name Calculation formula
H, mm Opening height 1,600–5,700
B, mm Opening width 1,800–5,800
Specifications
Parameter Value Notes
Wind load, Pa CLASS1 (up to 82) For gates 6,000 × 6,000 mm
Wind load, Pa CLASS2 (up to 90) For gates 5,000 × 5,000 mm
Opening speed, m/s 2.0 Gates up to 3,000 × 3,000 mm
Opening speed, m/s 1.5 Gates up to 5,000 × 5,000 mm
Opening speed, m/s 1,0 Gates up to 6,000 × 6,000 mm
Closing speed, m/s 0.5
Operating temperature range, °С -30…+50 When using the rack and drive heating system; when operating in a temperature range of -16…-30 °C, the gate design does not have reinforcement on the leaf, and transparent sections cannot be installed; "Security Profile" option is not available
Power, W 1,500
IP protection class 54 End positions are tracked by encoder
Supply voltage, V 220 V / 50 Hz Single phase
Supply voltage, V 380 V / 50 Hz Three-phase
Number of cycles 1,500,000 Depends on operating conditions
Wind load, Pa CLASS3 (up to 120) For gates 3,000 × 3,000 mm
Operating Conditions

Wind load resistance is given for SpeedRoll series doors in the closed position. Gates are not used in places with unstable and high wind loads caused by natural or man-made factors, such as: buildings located on sea coasts or in the mountains; multi-level heated underground parking lots with multiple entrances and exits; production facilities with powerful supply and exhaust ventilation; in buildings of complex configuration with many gate openings, where strong drafts may occur. If one or more of the above factors are present, it is recommended to use a SpeedFold series door or a HSSD series spiral door.

To ensure reliable and uninterrupted operation of the gate, it is recommended to carry out regular technical inspection and maintenance.

Manual opening and closing of the gate is done using a crank.

Do not subject the gate to impacts or interfere with its free opening and closing.

Do not allow the PVC sheet guide to get dirty.

It is prohibited to stand in the opening while the gate is opening and closing to avoid injury.

Make sure that there are no foreign objects in the opening when opening and closing the gate.

The self-healing function of the door leaf in the guides is used to operate the gate in emergency conditions, for example, in the event of an unintentional collision with a vehicle, and is not intended to work when the door leaf is deliberately and systematically knocked out of the guides. The functionality of the function is ensured by the ability of the “zipper” installed on the door leaf to come out of the plastic guides. The functionality of the function cannot be ensured in the event of impacts that exceed the strength parameters of the individual components of the web and system elements. For example, in the event of a collision with a road surface at high speed, impacts with sharp objects, impacts on the top of the gate with raised forks of a forklift, etc.

Additional Information

All the DoorHan products are loaded with hydraulic crane or fork-lift truck with 2 m long forks. Customer or installer is recommended to use similar equipment. Truck fork should go under the wooden pallet, provided by the customer, and protrude from its other side. When lifting with crane or other lifting equipment use slings of corresponding lifting capacity.

Warranty

The buyer is provided with a performance guarantee for high-speed rolling gates produced by the DoorHan concern for a period of 1 year for retail and for a period of 2 years for dealer orders from the date of purchase.

Checkout
Managers of the company will answer all
questions by phone: